NeoBrainSeg

From LRDE

Revision as of 11:20, 3 May 2018 by Thierry Géraud (talk | contribs) (Created page with "== The Challenge of Cerebral MRI in Neonates: A New Method using Mathematical Morphology for the Segmentation of Structures Including DEHSI == ==== Publication ==== The rela...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

The Challenge of Cerebral MRI in Neonates: A New Method using Mathematical Morphology for the Segmentation of Structures Including DEHSI

Publication

The related publication is available from this page.

Bibtex entry: @Article{ xu.18.media, author = {Yongchao Xu and Baptiste Morel and Sonia Dahdouh and \'Elodie Puybareau and Alessio Virz\`i and H\'el\`ene Urien and Thierry~G\'eraud and Catherine Adamsbaum and Isabelle Bloch}, title = {The Challenge of Cerebral Magnetic Resonance Imaging in Neonates: {A} New Method using Mathematical Morphology for the Segmentation of Structures Including Diffuse Excessive High Signal Intensities}, journal = {Medical Image Analysis}, year = 2018, pages = {1--23}, abstract = {Preterm birth is a multifactorial condition associated with increased morbidity and mortality. Diffuse excessive high signal intensity (DEHSI) has been recently described on T2-weighted MR sequences in this population and thought to be associated with neuropathologies. To date, no robust and reproducible method to assess the presence of white matter hyperintensities has been developed, perhaps explaining the current controversy over their prognostic value. The aim of this paper is to propose a new semi-automated framework to detect DEHSI on neonatal brain MR images having a particular pattern due to the physiological lack of complete myelination of the white matter. A novel method for semi- automatic segmentation of neonatal brain structures and DEHSI, based on mathematical morphology and on max-tree representations of the images is thus described. It is a mandatory first step to identify and clinically assess homogeneous cohorts of neonates for DEHSI and/or volume of any other segmented structures. Implemented in a user-friendly interface, the method makes it straightforward to select relevant markers of structures to be segmented, and if needed, apply eventually manual corrections. This method responds to the increasing need for providing medical experts with semi-automatic tools for image analysis, and overcomes the limitations of visual analysis alone, prone to subjectivity and variability. Experimental results demonstrate that the method is accurate, with excellent reproducibility and with very few manual corrections needed. Although the method was intended initially for images acquired at 1.5T, which corresponds to usual clinical practice, preliminary results on images acquired at 3T suggest that the proposed approach can be generalized.}, url = {http://publications.lrde.epita.fr/xu.18.media.pdf}, note = {To appear} }


Software

Available soon...

If this software is used in the context of a scientific publication, please cite the paper mentioned above.

Copyright Notice

LRDE is the copyright holder of all the codes included in the archive.

You are allowed to use these codes and software for research purpose. If so, please specify the following copyright: "Copyright (c) 2018. EPITA Research and Development Laboratory (LRDE)". You are not allowed to redistribute these codes. You are not allowed to redistribute the dehsi.nii example.